Aluminum Rooftop Equipment Supports (All stands are engineered for Dade County, Broward County, Palm Beach County &Southern Standard Building Codes.)
1] Hurricane Stands. Designed to support any configuration of rooftop air Conditioning condenser units . Designs are engineered to specifications Of local county building codes. Designed to move A/C Units above roof for ease of RE_ROOFING and increase circulation
A] Stock Stands .. (Coastal & Non Coastal) Broward County, Palm Beach County& State (engineering details in engineering section) Adjustable 18 & 24 inch legs & I Beams make up stands as shown in pictures, which will support from one to 6 units stands are designed for installation at heights from sea level to 100 feet.I beams can be located in various spots All stands are rated to accept specific sized units that are engineered for that location. ( Pictures # 1, 2, 3, 4 )
Dade County (engineering details in engineering section) Adjustable 20 & 26 inch legs & I Beams make up stands as shown in pictures, which will support from one to 5 units stands are designed for installation at heights from sea level to 300 feet. I beams can be located in various spots All stands are rated to accept specific sized units that are engineered for that location. ( Pictures # 1, 2, 3, 4 )
Stock list.all areas 2,3,4 ft long stands ( with two I beams ) for one A/C unit with 2 leg assemblies 12 to 36 ht above roof 5,6,7,8,9 ft long stands (with two I beams) for two A/C units with 2 leg assemblies 12 to 36 ht above roof 9,10,12,14 ft long stands (with two I beams) for three / four A/C units with 3 /4 leg assemblies 12 to 36 ht above roof 15,16,17,18 ft long stands (with two I beams) for four / five A/C units with 4 /5 leg assemblies 12 to 36 ht above roof.
B] Custom Designed Stands..(Coastal & Non Coastal) All Areas 3 foot 18 foot long Stands, any configuration, either one piece welded construction or adjustable in sections. Custom units will accommodate A/C condenser stands from One ton to 100 tons ( Pictures #6,7 )
2] Aluminum Structural Supports A] Chilled Water Pipe Electrical & Condensate Line Support Systems All Area .. Pictures # 6,# 7,
B] Custom Air Handler Stands. Interior closets construction C] Power Poles.3 x 3 inch square Aluminum Tubes from 8 ft to 15 ft high used for concealing electrical and computer conduit lines for store & office remodeling.
D] Post Extension For use in extending the height of rooftop structure E] Duct Supports..Aluminum structure to support rooftop duct installations F] Rooftop Walk & Work Supports supports for roof works stations Rubber Products
1] Rubber Vibration Pads Pads for use with A/C Condensers and small motors A] Recycled Rubber 3/8 Pads & 3/ 4 Pads 16 x 16 .precut to 64 pads 2x2 B] Natural Rubber 3/4 Pads 18 x 18 .precut to 81 pads 2x2 |
| |
|
|
|
Avcoa 3350 Burris Road, Ft. Lauderdale, FL 33314 Toll Free: 1-800-266-7212 Phone: 1-954-584-6001 Fax 1-954-584-6003 2003 Avcoa. All Rights Reserved. Site Designed & Hosted By: Bratpak Internet Services | |